Orisinil
BYD Atto 3

Sensor tekanan dan suhu

Kode OE / Material

13264743-00EM2E-8114460
$18USD
Tersedia
Ketersediaan kualitas

Spesifikasi Teknis

Model Kendaraan
BYD Atto 3
Konfigurasi Kemudi
Universal (Setir Kiri & Kanan)

Pengiriman & Pengembalian

Dikirim ke seluruh dunia dari Tiongkok melalui pengiriman udara atau laut. Pengiriman standar 5–30 hari kerja, ekspres 2–10 hari kerja. Biaya pengiriman dihitung saat checkout.

Jendela pengembalian 7 hari untuk barang yang belum digunakan dalam kemasan asli. Hubungi kami sebelum mengembalikan barang apa pun.

Sensor tekanan dan suhu Panduan BengkelBYD Atto 3

Pressure & Temperature Sensor - Removal and Installation

Removal

  1. Power off the low voltage electrical system. See Power-off and Power-on of Low Voltage Electrical System
  2. Recover the refrigerant See Recovery and Filling of Refrigerant
  3. Disconnect one connector of pressure & temperature sensor.
    Sensor tekanan dan suhu — BYD BYD Atto 3 — OE 13264743-00, EM2E-8114460
  4. Remove the pressure & temperature sensor.
    Sensor tekanan dan suhu — BYD BYD Atto 3 — OE 13264743-00, EM2E-8114460

Installation

  1. Follow the removal steps in reverse order to install.

Caution For the installation, all “O-rings” of the pipeline must be replaced, and refrigerant oil shall be applied on the surface of the seal rings and the seal rings shall be connected according to the stipulated torque.

Pressure Sensor - Removal and Installation

Removal

  1. Power off the low voltage electrical system. See Power-off and Power-on of Low Voltage Electrical System
  2. Recover the refrigerant See Recovery and Filling of Refrigerant
  3. Disconnect 1 connector of pressure sensor.
    Sensor tekanan dan suhu — BYD BYD Atto 3 — OE 13264743-00, EM2E-8114460
  4. Disconnect the rubber cover of pressure sensor.
  5. Disconnect 1 connectors.
  6. Remove the pressure sensor.
    Sensor tekanan dan suhu — BYD BYD Atto 3 — OE 13264743-00, EM2E-8114460

Install

  1. The installation is performed in reverse order of removal.

Caution For the installation, all “O-rings” of the pipeline must be replaced, and refrigerant oil shall be applied on the surface of the seal rings and the seal rings shall be connected according to the stipulated torque.

Plate Temperature Sensor - Removal and Installation

Removal

  1. Power off the low voltage electrical system. See Power-off and Power-on of Low Voltage Electrical System
  2. Remove the plate end temperature sensor.
    Sensor tekanan dan suhu — BYD BYD Atto 3 — OE 13264743-00, EM2E-8114460
  3. Disconnect 1 connectors.
  4. Detach the plate end temperature sensor from the compressor discharge pipe assembly 1, and take it out.

Install

  1. The installation is performed in reverse order of removal.